OAHI Standards of Practice
1. INTRODUCTION
1.1 The Ontario Association of Home Inspectors
(OAHI) is a not-for-profit association established in 1987.
In 1994, it became a self-regulating professional body when
the OAHI Act received royal assent (passage of Bill Pr158).
Membership in OAHI is voluntary and its members include
private, fee-paid home inspectors. OAHI's objectives include
promotion of excellence within the profession and continual
improvement of its members' inspection services to the public.
(The OAHI acknowledges The American Society of Home Inspectors
®, Inc. (ASHI ® for the use of their Standards of
Practice - version January 1, 2000.)
2. PURPOSE AND SCOPE
2.1 The purpose of these Standards of
Practice is to establish a minimum and uniform standard
for private, fee-paid home inspectors who are members of
the Ontario Association of Home Inspectors. Home Inspections
performed to these Standards of Practice are intended to
provide the client with information regarding the condition
of the systems and components of the home as inspected at
the time of the Home Inspection.
2.2 Inspectors shall:
A. inspect :
1. readily accessible systems and components
of homes listed in these Standards of Practice.
2. installed systems and components of
homes listed in these Standards of Practice.
B. report :
1. on those systems and components inspected
which, in the professional opinion of the inspector, are
significantly deficient or are near the end of their service
lives.
2. a reason why, if not self-evident,
the system or component is significantly deficient or
near the end of its service life.
3. the inspector's recommendations to
correct or monitor the reported deficiency.
4. on any systems and components designated
for inspection in these Standards of Practice which were
present at the time of the Home Inspection but were not
inspected and a reason they were not inspected.
2.3 These Standards of Practice are not intended
to limit inspectors from:
A. including other inspection services,
systems or components in addition to those required by
these Standards of Practice.
B. specifying repairs, provided the inspector
is appropriately qualified and willing to do so.
C. excluding systems and components from
the inspection if requested by the client.
3. STRUCTURAL SYSTEM
3.1 The inspector shall
A. inspect
1. the structural components including
foundation and framing.
2. by probing a representative number
of structural components where deterioration is suspected
or where clear indications of possible deterioration exist.
Probing is NOT required when probing would damage any
finished surface or where no deterioration is visible.
B. describe
1. the foundation and report the methods
used to inspect the under-floor crawl space
b the floor structure
3. the wall structure
4. the ceiling structure
5. the roof structure and report the
methods used to inspect the attic.
3.2 The inspector is NOT required to
A. provide any engineering service
or architectural service
B. offer an opinion as to the adequacy
of any structural system or component
4. EXTERIOR
4.1 The inspector shall:
A. inspect :
1. the exterior wall covering, flashing
and trim.
2. all exterior doors.
3. attached decks, balconies, stoops,
steps, porches, and their associated railings.
4. the eaves, soffits, and fascias where
accessible from the ground level.
5. the vegetation, grading, surface drainage,
and retaining walls on the property when any of these
are likely to adversely affect the building.
6. walkways, patios, and driveways leading
to dwelling entrances.
describe the exterior wall covering.
4.2 The inspector is NOT required to:
A. inspect :
1. screening, shutters, awnings, and
similar seasonal accessories.
fences.
2. geological, geotechnical or hydrological
conditions.
3. recreational facilities.
4. outbuildings.
5. seawalls, break-walls, and docks.
6. erosion control and earth stabilization
measures.
5. ROOF SYSTEM
5.1 The inspector shall:
A. inspect :
1. the roof covering.
2. the roof drainage systems.
3. the flashings.
4. the skylights, chimneys, and roof
penetrations.
5. describe the roof covering and report
the methods used to inspect the roof.
5.2 The inspector is NOT required to:
A. inspect :
1. antennae.
2. interiors of flues or chimneys which
are not readily accessible.
3. other installed accessories.
6. PLUMBING SYSTEM
6.1 The inspector shall:
A. inspect :
1. the interior water supply and distribution
systems including all fixtures and faucets.
2. the drain, waste and vent systems
including all fixtures.
3. the water heating equipment.
4. the vent systems , flues, and chimneys.
5. the fuel storage and fuel distribution
systems.
6. the drainage sumps, sump pumps, and
related piping.
B. describe :
1. the water supply, drain, waste, and
vent piping materials.
2. the water heating equipment including
the energy source.
3. the location of main water and main
fuel shut-off valves.
6.2 The inspector is NOT required to:
A. inspect :
1. the clothes washing machine connections.
2. the interiors of flues or chimneys
which are not readily accessible.
3. wells, well pumps, or water storage
related equipment.
4. water conditioning systems.
5. solar water heating systems.
6. fire and lawn sprinkler systems.
7. private waste disposal systems.
B. determine:
1. whether water supply and waste disposal
systems are public or private.
2. the quantity or quality of the water
supply.
3. operate safety valves or shut-off
valves.
7. ELECTRICAL SYSTEM
7.1 The inspector shall:
A. inspect :
1. the service drop.
2. the service entrance conductors, cables,
and raceways.
3. the service equipment and main disconnects.
4. the service grounding.
5. the interior components of service
panels and sub panels.
6. the conductors.
7. the over current protection devices.
8. a representative number of installed
lighting fixtures, switches, and receptacles.
9. the ground fault circuit interrupters.
B. describe:
1. the amperage and voltage rating of the service.
2. the location of main disconnect(s)
and sub panels.
3. the wiring methods.
C. report:
1. on the presence of solid conductor
aluminum branch circuit wiring.
2. on the absence of smoke detectors.
7.2 The inspector is NOT required to:
A. inspect :
1. the remote control devices unless
the device is the only control device.
2. the alarm systems and components.
3. the low voltage wiring, systems and
components.
4. the ancillary wiring, systems and
components not a part of the primary electrical power
distribution system.
5. measure amperage, voltage, or impedance
8. HEATING SYSTEM
8.1 The inspector shall:
A. inspect :
1. the installed heating equipment.
2. the vent systems, flues, and chimneys.
B. describe:
1. the energy source.
2. the heating method by its distinguishing
characteristics.
8.2 The inspector is NOT required to:
A. inspect :
1. the interiors of flues or chimneys
which are not readily accessible.
2. the heat exchanger.
3. the humidifier or dehumidifier.
4. the electronic air filter.
5. the solar space heating system.
6. determine heat supply adequacy or
distribution balance.
9. AIR CONDITIONING SYSTEMS
9.1 The inspector shall:
A. inspect the installed central and
through-wall cooling equipment.
B. describe:
1. the energy source
2. the cooling method by its distinguishing
characteristics.
9.2 The inspector is NOT required to:
A. inspect electronic air filters.
B. determine cooling supply adequacy
or distribution balance.
10. INTERIOR
10.1 The inspector shall:
A. inspect:
1. the walls, ceilings, and floors.
2. the steps, stairways, and railings.
3. the countertops and a representative
number of installed cabinets.
4. a representative number of doors and
windows.
5. garage doors and garage door operators.
10.2 The inspector is NOT required to:
A. inspect:
1. the paint, wallpaper, and other finish treatments.
2. the carpeting.
3. the window treatments.
4. the central vacuum systems.
5. the household appliances.
6. recreational facilities.
11. INSULATION & VENTILATION
11.1 The inspector shall:
A. inspect:
1. the insulation and vapour retarders in unfinished
spaces.
2. the ventilation of attics and foundation
areas.
3. the mechanical ventilation systems.
B. describe:
1. the insulation and vapour retarders in unfinished
spaces.
2. the absence of insulation in unfinished
spaces at conditioned surfaces.
11.2 The inspector is NOT required to:
A. disturb insulation or vapour retarders.
B. determine indoor air quality.
12. FIREPLACES AND SOLID FUEL BURNING APPLIANCES
12.1 The inspector shall:
A. inspect:
1. the system components.
2. the vent systems, flues, and chimneys.
B. describe:
1. the fireplaces and solid fuel burning appliances.
2. the chimneys.
12.2 The Inspector is NOT required to:
A. inspect:
1. the interiors of flues or chimneys.
2. the fire screens and doors.
3. the seals and gaskets.
4. the automatic fuel feed devices.
5. the mantles and fireplace surrounds.
6. the combustion make-up air devices.
7. the heat distribution assists whether
gravity controlled or fan assisted.
B. ignite or extinguish fires.
C. determine draft characteristics.
D. move fireplace inserts or stoves
or firebox contents.
13. GENERAL LIMITATIONS AND EXCLUSIONS
13.1 General limitations:
A. Inspections performed in accordance with these
Standards of Practice:
1. are not technically exhaustive.
2. will not identify concealed conditions
or latent defects.
B. These Standards of Practice are applicable
to buildings with four or fewer dwelling units and their
garages or carports.
13.2 General exclusions:
A. The inspector is not required to
perform any action or make any determination unless specifically
stated in these Standards of Practice, except as may be
required by lawful authority.
B. Inspectors are NOT required to determine:
1. the condition of systems or components which
are not readily accessible.
2. the remaining life of any system or
component.
3. the strength, adequacy, effectiveness,
or efficiency of any system or component.
4. the causes of any condition or deficiency.
5. the methods, materials, or costs of
corrections.
6. future conditions including, but not
limited to, failure of systems and components.
7. the suitability of the property for
any specialized use.
compliance with regulatory requirements (codes, regulations,
laws, ordinances, etc.).
8. the market value of the property or
its marketability.
9. the advisability of the purchase of
the property.
10. the presence of potentially hazardous
plants or animals including, but not limited to wood destroying
organisms or diseases harmful to humans.
11. the presence of any environmental
hazards including, but not limited to toxins, carcinogens,
noise, and contaminants in soil, water, and air.
12. the effectiveness of any system installed
or methods utilized to control or remove suspected hazardous
substances.
13. the operating costs of systems or
components.
14. the acoustical properties of any
system or component.
C. Inspectors are NOT required to offer:
1. or perform any act or service contrary to
law.
2. or perform engineering services.
3. or perform work in any trade or any
professional service other than home inspection.
4. warranties or guarantees of any kind.
D. Inspectors are NOT required to operate:
1. any system or component which is shut down
or otherwise inoperable.
2. any system or component which does
not respond to normal operating controls.
3. shut-off valves.
E. Inspectors are NOT required to enter:
1. any area which will, in the opinion of the
inspector, likely be dangerous to the inspector or other
persons or damage the property or
2. its systems or components.
3. the under-floor crawl spaces or attics
which are not readily accessible.
F. Inspectors are NOT required to inspect:
1. underground items including, but not limited
to underground storage tanks or other underground indications
of their presence, whether abandoned or active.
2. systems or components which are not
installed.
3. decorative items.
4. systems or components located in areas
that are not entered in accordance with these Standards
of Practice.
5. detached structures other than garages
and carports.
6.common elements or common areas in
multi-unit housing, such as condominium properties or
cooperative housing.
G. Inspectors are NOT required to:
1. perform any procedure or operation which will,
in the opinion of the inspector, likely be dangerous to
the inspector or other persons or damage the property
or its systems or components.
2. move suspended ceiling tiles, personal
property, furniture, equipment, plants, soil, snow, ice,
or debris.
3. dismantle any system or component,
except as explicitly required by these Standards of Practice.
Glossary of Terms
ALARM SYSTEMS
Warning devices, installed or free-standing, including but
not limited to: carbon monoxide detectors, flue gas and other
spillage detectors, security equipment, ejector pumps and
smoke alarms.
ARCHITECTURAL SERVICE
Any practice involving the art and science of building design
for construction of any structure or grouping of structures
and the use of space within and surrounding the structures
or the design for construction, including but not specifically
limited to, schematic design, design development, preparation
of construction contract documents, and administration of
the construction contract.
AUTOMATIC SAFETY CONTROLS:
Devices designed and installed to protect systems and components
from unsafe conditions.
COMPONENT:
A part of a system.
DECORATIVE
Ornamental; not required for the operation of the essential
systems and components of a home.
DESCRIBE:
To report a system or component by its type or other observed,
significant characteristics to distinguish it from other systems
or components.
DISMANTLE:
To take apart or remove any component, device or piece of
equipment that would not be taken apart or removed by a homeowner
in the course of normal and routine home owner maintenance.
ENGINEERING SERVICE:
Any professional service or creative work requiring engineering
education, training, and experience and the application of
special knowledge of the mathematical, physical and engineering
sciences to such professional service or creative work as
consultation, investigation, evaluation, planning, design
and supervision of construction for the purpose of assuring
compliance with the specifications and design, in conjunction
with structures, buildings, machines, equipment, works or
processes.
FURTHER EVALUATION:
Examination and analysis by a qualified professional, tradesman
or service technician beyond that provided by the home inspection.
HOME INSPECTION:
The process by which an inspector visually examines the readily
accessible systems and components of a home and which describes
those systems and components in accordance with these Standards
of Practice.
HOUSEHOLD APPLIANCES:
Kitchen, laundry, and similar appliances, whether installed
or free-standing.
INSPECT:
To examine readily accessible systems and components of a
building in accordance with these Standards of Practice, using
normal operating controls and opening readily open able access
panels.
INSPECTOR:
A person hired to examine any system or component of a building
in accordance with these Standards of Practice.
INSTALLED:
Attached such that removal requires tools.
NORMAL OPERATING CONTROLS:
Devices such as thermostats, switches or valves intended to
be operated by the homeowner.
READILY ACCESSIBLE:
Available for visual inspection without requiring moving of
personal property, dismantling, destructive measures, or any
action which will likely involve risk to persons or property.
READILY OPENABLE ACCESS PANEL:
A panel provided for homeowner inspection and maintenance
that is within normal reach, can be removed by one person,
and is not sealed in place.
RECREATIONAL FACILITIES:
Spas, saunas, steam baths, swimming pools, exercise, entertainment,
athletic, playground or other similar equipment and associated
accessories.
REPORT:
To communicate in writing.
REPRESENTATIVE NUMBER:
One component per room for multiple similar interior components
such as windows and electric outlets; one component on each
side of the building for multiple similar exterior components.
ROOF DRAINAGE SYSTEMS:
Components used to carry water off a roof and away from a
building.
SIGNIFICANTLY DEFICIENT:
Unsafe or not functioning.
SHUT DOWN:
A state in which a system or component cannot be operated
by normal operating controls.
SOLID FUEL BURNING APPLIANCES:
A hearth and fire chamber or similar prepared place in which
a fire may be built and which is built in conjunction with
a chimney; or a listed assembly of a fire chamber, its chimney
and related factory-made parts designed for unit assembly
without requiring field construction.
STRUCTURAL COMPONENT:
A component which supports non-variable forces or weights
(dead loads) and variable forces or weights (live loads).
SYSTEM:
A combination of interacting or interdependent components,
assembled to carry out one or more functions.
TECHNICALLY EXHAUSTIVE:
An investigation that involves dismantling, the extensive
use of advanced techniques, measurements, instruments, testing,
calculations, or other means.
UNDERFLOOR CRAWL SPACE:
The area within the confines of the foundation and between
the ground and the underside of the floor.
UNSAFE:
A condition in a readily accessible, installed system or component
which is judged to be a significant risk of personal injury
during normal, day-to-day use. The risk may be due to damage,
deterioration, improper installation or a change in accepted
residential construction standards.
WIRING METHODS:
Identification of electrical conductors or wires by their
general type, such as "non-metallic sheathed cable"
("Romex"), "armoured cable" ("BX")
or "knob and tube", etc. |